Force 50 SeaSerpent vs SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding
Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems
The Unifire Force 50 SeaSerpent and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding are both fire suppression systems products. Key difference: Operating Pressure — Force 50 SeaSerpent is 10 bar vs SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding at 100 bar.
Force 50 SeaSerpent
SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding
Specification comparison
| Specification | Force 50 SeaSerpent | SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding |
|---|---|---|
| Flow Rate | 2000 lpm | |
| Flow Rate (Imperial) | 530 gpm | |
| Operating Pressure | 10 bar | 100 bar |
| Pipe Diameter | 50 mm | |
| Horizontal Movement | 360 degrees | |
| Vertical Movement | 180 degrees | |
| Material | Stainless Steel 316L (marine-grade, acid-proof) | AISI 316 stainless steel piping |
| Motor Type | 24V DC brushless (BLDC) | |
| Hose Connections | Up to 3 fire hoses | |
| Mounting | Portable mounting pipe and valve (quick install/remove) | |
| Agent Type | High-pressure water mist (pure fresh water) | |
| Nozzle Type | Open deluge nozzle | |
| Droplet Size | 10 - 50 micron | |
| System Configuration | Dry pipe with manual activation (total flooding) | |
| Activation Method | Manual from valve operation panel (VOP) or bridge mimic panel | |
| Safe for Personnel | Yes (pure water, non-toxic) | |
| Safe for Electrical Equipment | Yes (IP 23 or better) |
Certification comparison
| Certification | Force 50 SeaSerpent | SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding |
|---|---|---|
| BV | — Not listed | ✓ |
| CCS | — Not listed | ✓ |
| DNV | — Not listed | ✓ |
| LR | — Not listed | ✓ |
| MED | — Not listed | ✓ |
| NK | — Not listed | ✓ |
| SOLAS | — Not listed | ✓ |
| USCG | — Not listed | ✓ |
Other Fire Suppression Systems comparisons
Data sources
SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding