Force 50 Marine Fire Monitor vs SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems
The Unifire Force 50 Marine Fire Monitor and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application are both fire suppression systems products certified to SOLAS. Key difference: Material — Force 50 Marine Fire Monitor is Stainless Steel 316L (marine-grade, acid-proof) vs SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application at AISI 316 stainless steel piping.
Force 50 Marine Fire Monitor
SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
Specification comparison
| Specification | Force 50 Marine Fire Monitor | SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application |
|---|---|---|
| Flow Rate | 2200 lpm | |
| Flow Rate (Imperial) | 580 gpm | |
| Max Pressure | 12 bar | |
| Pipe Diameter | 50 mm | |
| Horizontal Movement | 360 degrees | |
| Vertical Movement | 180 degrees | |
| Material | Stainless Steel 316L (marine-grade, acid-proof) | AISI 316 stainless steel piping |
| Weight | 13 kg | |
| Motor Type | 24V DC brushless (BLDC), IP68 laser-welded stainless steel enclosure | |
| Base Connections | 2" male BSP or flange (ANSI, DIN, JIS) | |
| Compatible Nozzles | INTEG 50, JETRANGE, Smooth Bore (24mm or 32mm) | |
| Agent Type | High-pressure water mist (pure fresh water) | |
| Operating Pressure | 100 bar | |
| Nozzle Type | Open nozzle for local application | |
| Detection Type | Heat, smoke, or flame sensors (application dependent) | |
| Activation Method | Automatic via detection system; manual override available | |
| System Configuration | Dry pipe with automatic activation per section | |
| Protected Equipment | Main engines, auxiliary engines, boiler fronts, oil separators, incinerators | |
| Safe for Electrical Equipment | Yes (IP 23 or better) |
Certification comparison
| Certification | Force 50 Marine Fire Monitor | SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application |
|---|---|---|
| BV | — Not listed | ✓ |
| CCS | — Not listed | ✓ |
| DNV | — Not listed | ✓ |
| LR | — Not listed | ✓ |
| MED | — Not listed | ✓ |
| NK | — Not listed | ✓ |
| SOLAS | ✓ | ✓ |
| USCG | — Not listed | ✓ |
Other Fire Suppression Systems comparisons
Data sources
SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
Data from ttr-cms.ttrbilisim.com.tr ·
View original