FlameRanger Autonomous Robotic Fire Suppression System vs SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Unifire FlameRanger Autonomous Robotic Fire Suppression System and Danfoss Semco SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00) are both fire suppression systems products certified to SOLAS.

FlameRanger Autonomous Robotic Fire Suppression System
SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)

Specification comparison

Specification FlameRanger Autonomous Robotic Fire Suppression System SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
Response Time <15 seconds
Simultaneous Fire Tracking 4 fires
Robotic Nozzles Per System 2 nozzles
Detection Type Triple IR flame detection (FGD IR3) + thermal imaging (VisionTIR FireTIR)
Targeting 3D dynamic fire localization and tracking
Operation Mode Fully autonomous with remote human override capability
Agent Type Water-based (compatible with foam)
Software Proprietary in-house designed electronics and software
Remote Access Global remote monitoring and override via web interface
Nozzle ID BT
Operating Pressure 60 bar
K-factor 1.258
Max Ceiling Height 1.5 m
Nozzle Spacing 2.7 x 3.0 m
Max Distance to Bulkhead Half spacing
Orientation Pendent
Material Nozzle head: CuZn36Pb2As (brass) NiSn coated; Top: AISI 316L
Pipe Connection 12mm DIN 2353 M12L
Part Number 8068629

Certification comparison

Certification FlameRanger Autonomous Robotic Fire Suppression System SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
DNV — Not listed ✓
LR — Not listed ✓
SOLAS ✓ ✓

Other Fire Suppression Systems comparisons

Data sources

FlameRanger Autonomous Robotic Fire Suppression System
Data from unifire.com ·
View original
SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
Data from components.semcomaritime.com ·
View original