FlameRanger Autonomous Robotic Fire Suppression System vs SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Unifire FlameRanger Autonomous Robotic Fire Suppression System and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application are both fire suppression systems products certified to SOLAS. Key difference: Detection Type — FlameRanger Autonomous Robotic Fire Suppression System is Triple IR flame detection (FGD IR3) + thermal imaging (VisionTIR FireTIR) vs SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application at Heat, smoke, or flame sensors (application dependent).

FlameRanger Autonomous Robotic Fire Suppression System
SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application

Specification comparison

Specification FlameRanger Autonomous Robotic Fire Suppression System SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
Response Time <15 seconds
Simultaneous Fire Tracking 4 fires
Robotic Nozzles Per System 2 nozzles
Detection Type Triple IR flame detection (FGD IR3) + thermal imaging (VisionTIR FireTIR) Heat, smoke, or flame sensors (application dependent)
Targeting 3D dynamic fire localization and tracking
Operation Mode Fully autonomous with remote human override capability
Agent Type Water-based (compatible with foam) High-pressure water mist (pure fresh water)
Software Proprietary in-house designed electronics and software
Remote Access Global remote monitoring and override via web interface
Operating Pressure 100 bar
Nozzle Type Open nozzle for local application
Activation Method Automatic via detection system; manual override available
Material AISI 316 stainless steel piping
System Configuration Dry pipe with automatic activation per section
Protected Equipment Main engines, auxiliary engines, boiler fronts, oil separators, incinerators
Safe for Electrical Equipment Yes (IP 23 or better)

Certification comparison

Certification FlameRanger Autonomous Robotic Fire Suppression System SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
BV — Not listed ✓
CCS — Not listed ✓
DNV — Not listed ✓
LR — Not listed ✓
MED — Not listed ✓
NK — Not listed ✓
SOLAS ✓ ✓
USCG — Not listed ✓

Other Fire Suppression Systems comparisons

Data sources

FlameRanger Autonomous Robotic Fire Suppression System
Data from unifire.com ·
View original
SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
Data from ttr-cms.ttrbilisim.com.tr ·
View original