AquaMist ULF Marine Water Mist System vs SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Tyco Fire Protection (Johnson Controls) AquaMist ULF Marine Water Mist System and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding are both fire suppression systems products certified to MED and SOLAS. Key difference: Operating Pressure — AquaMist ULF Marine Water Mist System is Up to 250 psi vs SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding at 100 bar.

AquaMist ULF Marine Water Mist System
SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding

Specification comparison

Specification AquaMist ULF Marine Water Mist System SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding
System Type Low-pressure water mist
Operating Pressure Up to 250 psi 100 bar
Agent Type Fresh water or seawater High-pressure water mist (pure fresh water)
Nozzle Types AM6, AM11, AM22, AM24, AM27, AM29, AM30, AM31, AM32, AM34
Configuration Wet pipe, dry pipe, preaction, deluge
Nozzle Type Open deluge nozzle
Droplet Size 10 - 50 micron
Material AISI 316 stainless steel piping
System Configuration Dry pipe with manual activation (total flooding)
Activation Method Manual from valve operation panel (VOP) or bridge mimic panel
Safe for Personnel Yes (pure water, non-toxic)
Safe for Electrical Equipment Yes (IP 23 or better)

Certification comparison

Certification AquaMist ULF Marine Water Mist System SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding
BV — Not listed ✓
CCS — Not listed ✓
DNV — Not listed ✓
LR — Not listed ✓
MED ✓ ✓
NK — Not listed ✓
SOLAS ✓ ✓
USCG — Not listed ✓