ANSUL Marine Low-Pressure CO2 System vs SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57)
Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems
The Tyco Fire Protection (Johnson Controls) ANSUL Marine Low-Pressure CO2 System and Danfoss Semco SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57) are both fire suppression systems products certified to SOLAS. Key difference: Operating Pressure — ANSUL Marine Low-Pressure CO2 System is 21 bar vs SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57) at 60 bar.
ANSUL Marine Low-Pressure CO2 System
SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57)
Unverified
Specification comparison
| Specification | ANSUL Marine Low-Pressure CO2 System | SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57) |
|---|---|---|
| Agent Type | Carbon dioxide (CO2) | |
| System Type | Low-pressure bulk storage | |
| Operating Pressure | 21 bar | 60 bar |
| Storage Capacity | 1,000 - 46,000 kg | |
| Storage Method | Refrigerated liquid CO2 | |
| Nozzle ID | AB (5-12-44-68-20-57) | |
| K-factor | 2.0 | |
| Flow Rate | 15.5 l/min | |
| Max Ceiling Height | 2.5 m | |
| Coverage Area | 12 (centric within cabin) m2 | |
| Activation Temperature | 57 C | |
| Orientation | Pendent | |
| Material | Nozzle head: CuZn36Pb2As (brass) NiSn coated; Top: AISI 316L | |
| Pipe Connection | 12mm DIN 2353 M12L | |
| Part Number | 8074115 |
Certification comparison
| Certification | ANSUL Marine Low-Pressure CO2 System | SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57) |
|---|---|---|
| DNV | — Not listed | ✓ |
| LR | — Not listed | ✓ |
| MED | ✓ | — Not listed |
| SOLAS | ✓ | ✓ |
| USCG | ✓ | — Not listed |
Other Fire Suppression Systems comparisons
Data sources
SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57)
Data from components.semcomaritime.com ·
View original