ANSUL Marine INERGEN 200-Bar Inert Gas System vs SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding
Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems
The Tyco Fire Protection (Johnson Controls) ANSUL Marine INERGEN 200-Bar Inert Gas System and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding are both fire suppression systems products certified to MED and SOLAS. Key difference: Agent Type — ANSUL Marine INERGEN 200-Bar Inert Gas System is INERGEN (52% N2, 40% Ar, 8% CO2) vs SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding at High-pressure water mist (pure fresh water).
ANSUL Marine INERGEN 200-Bar Inert Gas System
SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding
Specification comparison
| Specification | ANSUL Marine INERGEN 200-Bar Inert Gas System | SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding |
|---|---|---|
| Agent Type | INERGEN (52% N2, 40% Ar, 8% CO2) | High-pressure water mist (pure fresh water) |
| System Pressure | 200 bar | |
| Fire Classes | Class A, B, and C | |
| Ozone Depletion Potential | 0.0 | |
| Global Warming Potential | 0.0 | |
| Operating Pressure | 100 bar | |
| Nozzle Type | Open deluge nozzle | |
| Droplet Size | 10 - 50 micron | |
| Material | AISI 316 stainless steel piping | |
| System Configuration | Dry pipe with manual activation (total flooding) | |
| Activation Method | Manual from valve operation panel (VOP) or bridge mimic panel | |
| Safe for Personnel | Yes (pure water, non-toxic) | |
| Safe for Electrical Equipment | Yes (IP 23 or better) |
Certification comparison
| Certification | ANSUL Marine INERGEN 200-Bar Inert Gas System | SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding |
|---|---|---|
| BV | — Not listed | ✓ |
| CCS | — Not listed | ✓ |
| DNV | — Not listed | ✓ |
| LR | — Not listed | ✓ |
| MED | ✓ | ✓ |
| NK | — Not listed | ✓ |
| SOLAS | ✓ | ✓ |
| USCG | — Not listed | ✓ |
Other Fire Suppression Systems comparisons
Data sources
SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding
Data from ·