ANSUL Marine INERGEN 200-Bar Inert Gas System vs SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Tyco Fire Protection (Johnson Controls) ANSUL Marine INERGEN 200-Bar Inert Gas System and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application are both fire suppression systems products certified to MED and SOLAS. Key difference: Agent Type — ANSUL Marine INERGEN 200-Bar Inert Gas System is INERGEN (52% N2, 40% Ar, 8% CO2) vs SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application at High-pressure water mist (pure fresh water).

ANSUL Marine INERGEN 200-Bar Inert Gas System
SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application

Specification comparison

Specification ANSUL Marine INERGEN 200-Bar Inert Gas System SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
Agent Type INERGEN (52% N2, 40% Ar, 8% CO2) High-pressure water mist (pure fresh water)
System Pressure 200 bar
Fire Classes Class A, B, and C
Ozone Depletion Potential 0.0
Global Warming Potential 0.0
Operating Pressure 100 bar
Nozzle Type Open nozzle for local application
Detection Type Heat, smoke, or flame sensors (application dependent)
Activation Method Automatic via detection system; manual override available
Material AISI 316 stainless steel piping
System Configuration Dry pipe with automatic activation per section
Protected Equipment Main engines, auxiliary engines, boiler fronts, oil separators, incinerators
Safe for Electrical Equipment Yes (IP 23 or better)

Certification comparison

Certification ANSUL Marine INERGEN 200-Bar Inert Gas System SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
BV — Not listed ✓
CCS — Not listed ✓
DNV — Not listed ✓
LR — Not listed ✓
MED ✓ ✓
NK — Not listed ✓
SOLAS ✓ ✓
USCG — Not listed ✓

Other Fire Suppression Systems comparisons

Data sources

ANSUL Marine INERGEN 200-Bar Inert Gas System
Data from ansul.com ·
View original
SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
Data from ttr-cms.ttrbilisim.com.tr ·
View original