MXOne High-Performance Firefighting Turbine vs SEM-SAFE Accommodation Nozzle Type F (HNMP-4-10-2.04-57)

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Minimax MXOne High-Performance Firefighting Turbine and Danfoss Semco SEM-SAFE Accommodation Nozzle Type F (HNMP-4-10-2.04-57) are both fire suppression systems products certified to SOLAS. Key difference: Operating Pressure — MXOne High-Performance Firefighting Turbine is 4 - 16 bar vs SEM-SAFE Accommodation Nozzle Type F (HNMP-4-10-2.04-57) at 100 bar.

MXOne High-Performance Firefighting Turbine
SEM-SAFE Accommodation Nozzle Type F (HNMP-4-10-2.04-57)

Specification comparison

Specification MXOne High-Performance Firefighting Turbine SEM-SAFE Accommodation Nozzle Type F (HNMP-4-10-2.04-57)
Agent Type Water mist to full jet (variable spray patterns)
Operating Pressure 4 - 16 bar 100 bar
Discharge Time Continuous
Agent Capacity 4000 l/min
Coverage Area Up to 400 m2
Weight 945 kg
Dimensions 1590 x 1390 x 1942 mm
Temperature Range -15 to +55 C
Rotation Angle 360 degrees
Tilting Angle -19 to +43 degrees
Power Supply 400V/50Hz or 480V/60Hz
Nominal Current 34 A
Max Air Flow 31000 m3/h
Propeller Power 12.5 kW
Water Connection DN 125 (5 inch)
Nozzle ID F (3-02-48-4-22-57)
K-factor 2.04
Max Ceiling Height 2.5 m
Nozzle Spacing 2.5 m
Activation Temperature 57 C
Orientation Pendent
Max Distance to Bulkhead 1.25 m
Material CuZn36Pb2As (brass) coated with NiSn
Pipe Connection 10mm DIN 2353 M10S
Part Number 8068633

Certification comparison

Certification MXOne High-Performance Firefighting Turbine SEM-SAFE Accommodation Nozzle Type F (HNMP-4-10-2.04-57)
BV — Not listed ✓
DNV — Not listed ✓
LR — Not listed ✓
MED ✓ — Not listed
SOLAS ✓ ✓