Minifog Marine XP High-Pressure Water Mist System vs SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems
The Minimax Minifog Marine XP High-Pressure Water Mist System and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application are both fire suppression systems products certified to DNV and LR. Key difference: Agent Type — Minifog Marine XP High-Pressure Water Mist System is High-pressure water mist with optional fluorine-free foam vs SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application at High-pressure water mist (pure fresh water).
Minifog Marine XP High-Pressure Water Mist System
SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
Specification comparison
| Specification | Minifog Marine XP High-Pressure Water Mist System | SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application |
|---|---|---|
| Agent Type | High-pressure water mist with optional fluorine-free foam | High-pressure water mist (pure fresh water) |
| System Type | High-pressure total flooding and local application | |
| Coverage Area | Engine rooms, bilges, machinery spaces | |
| Fuel Compatibility | Diesel, heavy fuel oil, methanol, dual-fuel | |
| Compliance | IMO MSC.1/Circ. 1165 | |
| Activation | Automatic via fire detection system | |
| Operating Pressure | 100 bar | |
| Nozzle Type | Open nozzle for local application | |
| Detection Type | Heat, smoke, or flame sensors (application dependent) | |
| Activation Method | Automatic via detection system; manual override available | |
| Material | AISI 316 stainless steel piping | |
| System Configuration | Dry pipe with automatic activation per section | |
| Protected Equipment | Main engines, auxiliary engines, boiler fronts, oil separators, incinerators | |
| Safe for Electrical Equipment | Yes (IP 23 or better) |
Certification comparison
| Certification | Minifog Marine XP High-Pressure Water Mist System | SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application |
|---|---|---|
| BV | — Not listed | ✓ |
| CCS | — Not listed | ✓ |
| DNV | ✓ | ✓ |
| LR | ✓ | ✓ |
| MED | ✓ | ✓ |
| NK | — Not listed | ✓ |
| SOLAS | ✓ | ✓ |
| USCG | — Not listed | ✓ |