Minifog Marine Water Mist Local Application System vs SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Minimax Minifog Marine Water Mist Local Application System and Danfoss Semco SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00) are both fire suppression systems products certified to DNV and LR. Key difference: Operating Pressure — Minifog Marine Water Mist Local Application System is 4 bar vs SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00) at 60 bar.

Minifog Marine Water Mist Local Application System
SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)

Specification comparison

Specification Minifog Marine Water Mist Local Application System SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
Agent Type Water mist
System Type Low-pressure local application
Operating Pressure 4 bar 60 bar
Nozzle Type Impulse nozzles
Coverage Area Engine rooms - local equipment protection
Activation Automatic via fire detection and extinguishing control
Nozzle ID BT
K-factor 1.258
Max Ceiling Height 1.5 m
Nozzle Spacing 2.7 x 3.0 m
Max Distance to Bulkhead Half spacing
Orientation Pendent
Material Nozzle head: CuZn36Pb2As (brass) NiSn coated; Top: AISI 316L
Pipe Connection 12mm DIN 2353 M12L
Part Number 8068629

Certification comparison

Certification Minifog Marine Water Mist Local Application System SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
DNV ✓ ✓
LR ✓ ✓
MED ✓ — Not listed
SOLAS ✓ ✓

Other Fire Suppression Systems comparisons

Data sources

Minifog Marine Water Mist Local Application System
Data from minimax.com ·
View original
SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
Data from components.semcomaritime.com ·
View original