Minifog Marine Water Mist Local Application System vs SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57)
Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems
The Minimax Minifog Marine Water Mist Local Application System and Danfoss Semco SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57) are both fire suppression systems products certified to DNV and LR. Key difference: Operating Pressure — Minifog Marine Water Mist Local Application System is 4 bar vs SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57) at 60 bar.
Minifog Marine Water Mist Local Application System
SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57)
Specification comparison
| Specification | Minifog Marine Water Mist Local Application System | SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57) |
|---|---|---|
| Agent Type | Water mist | |
| System Type | Low-pressure local application | |
| Operating Pressure | 4 bar | 60 bar |
| Nozzle Type | Impulse nozzles | |
| Coverage Area | Engine rooms - local equipment protection | 12 (centric within cabin) m2 |
| Activation | Automatic via fire detection and extinguishing control | |
| Nozzle ID | AB (5-12-44-68-20-57) | |
| K-factor | 2.0 | |
| Flow Rate | 15.5 l/min | |
| Max Ceiling Height | 2.5 m | |
| Activation Temperature | 57 C | |
| Orientation | Pendent | |
| Material | Nozzle head: CuZn36Pb2As (brass) NiSn coated; Top: AISI 316L | |
| Pipe Connection | 12mm DIN 2353 M12L | |
| Part Number | 8074115 |
Certification comparison
| Certification | Minifog Marine Water Mist Local Application System | SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57) |
|---|---|---|
| DNV | ✓ | ✓ |
| LR | ✓ | ✓ |
| MED | ✓ | — Not listed |
| SOLAS | ✓ | ✓ |
Other Fire Suppression Systems comparisons
Data sources
SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57)
Data from components.semcomaritime.com ·
View original