Minifog Marine Water Mist Local Application System vs SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding
Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems
The Minimax Minifog Marine Water Mist Local Application System and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding are both fire suppression systems products certified to DNV and LR. Key difference: Agent Type — Minifog Marine Water Mist Local Application System is Water mist vs SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding at High-pressure water mist (pure fresh water).
Minifog Marine Water Mist Local Application System
SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding
Specification comparison
| Specification | Minifog Marine Water Mist Local Application System | SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding |
|---|---|---|
| Agent Type | Water mist | High-pressure water mist (pure fresh water) |
| System Type | Low-pressure local application | |
| Operating Pressure | 4 bar | 100 bar |
| Nozzle Type | Impulse nozzles | Open deluge nozzle |
| Coverage Area | Engine rooms - local equipment protection | |
| Activation | Automatic via fire detection and extinguishing control | |
| Droplet Size | 10 - 50 micron | |
| Material | AISI 316 stainless steel piping | |
| System Configuration | Dry pipe with manual activation (total flooding) | |
| Activation Method | Manual from valve operation panel (VOP) or bridge mimic panel | |
| Safe for Personnel | Yes (pure water, non-toxic) | |
| Safe for Electrical Equipment | Yes (IP 23 or better) |
Certification comparison
| Certification | Minifog Marine Water Mist Local Application System | SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding |
|---|---|---|
| BV | — Not listed | ✓ |
| CCS | — Not listed | ✓ |
| DNV | ✓ | ✓ |
| LR | ✓ | ✓ |
| MED | ✓ | ✓ |
| NK | — Not listed | ✓ |
| SOLAS | ✓ | ✓ |
| USCG | — Not listed | ✓ |