Minifog Marine Water Mist Local Application System vs SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Minimax Minifog Marine Water Mist Local Application System and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application are both fire suppression systems products certified to DNV and LR. Key difference: Agent Type — Minifog Marine Water Mist Local Application System is Water mist vs SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application at High-pressure water mist (pure fresh water).

Minifog Marine Water Mist Local Application System
SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application

Specification comparison

Specification Minifog Marine Water Mist Local Application System SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
Agent Type Water mist High-pressure water mist (pure fresh water)
System Type Low-pressure local application
Operating Pressure 4 bar 100 bar
Nozzle Type Impulse nozzles Open nozzle for local application
Coverage Area Engine rooms - local equipment protection
Activation Automatic via fire detection and extinguishing control
Detection Type Heat, smoke, or flame sensors (application dependent)
Activation Method Automatic via detection system; manual override available
Material AISI 316 stainless steel piping
System Configuration Dry pipe with automatic activation per section
Protected Equipment Main engines, auxiliary engines, boiler fronts, oil separators, incinerators
Safe for Electrical Equipment Yes (IP 23 or better)

Certification comparison

Certification Minifog Marine Water Mist Local Application System SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
BV — Not listed ✓
CCS — Not listed ✓
DNV ✓ ✓
LR ✓ ✓
MED ✓ ✓
NK — Not listed ✓
SOLAS ✓ ✓
USCG — Not listed ✓

Other Fire Suppression Systems comparisons

Data sources

Minifog Marine Water Mist Local Application System
Data from minimax.com ·
View original
SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
Data from ttr-cms.ttrbilisim.com.tr ·
View original