Marine Sprinkler System vs SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57)

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Minimax Marine Sprinkler System and Danfoss Semco SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57) are both fire suppression systems products certified to DNV and LR. Key difference: Coverage Area — Marine Sprinkler System is Cabins, restaurants, public spaces, corridors vs SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57) at 12 (centric within cabin) m2.

Marine Sprinkler System
SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57)

Specification comparison

Specification Marine Sprinkler System SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57)
Agent Type Water
System Type Automatic wet-pipe sprinkler
Coverage Area Cabins, restaurants, public spaces, corridors 12 (centric within cabin) m2
Nozzle Variants Standard, Undercover (concealed), Pop-Up
Activation Automatic (thermally activated bulb)
Nozzle ID AB (5-12-44-68-20-57)
Operating Pressure 60 bar
K-factor 2.0
Flow Rate 15.5 l/min
Max Ceiling Height 2.5 m
Activation Temperature 57 C
Orientation Pendent
Material Nozzle head: CuZn36Pb2As (brass) NiSn coated; Top: AISI 316L
Pipe Connection 12mm DIN 2353 M12L
Part Number 8074115

Certification comparison

Certification Marine Sprinkler System SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57)
BV ✓ — Not listed
DNV ✓ ✓
LR ✓ ✓
MED ✓ — Not listed
SOLAS ✓ ✓

Other Fire Suppression Systems comparisons

Data sources

Marine Sprinkler System
Data from minimax.com ·
View original
SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57)
Data from components.semcomaritime.com ·
View original