Marine Sprinkler System vs SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57)

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Minimax Marine Sprinkler System and Danfoss Semco SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57) are both fire suppression systems products certified to BV and DNV.

Marine Sprinkler System
SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57)

Specification comparison

Specification Marine Sprinkler System SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57)
Agent Type Water
System Type Automatic wet-pipe sprinkler
Coverage Area Cabins, restaurants, public spaces, corridors
Nozzle Variants Standard, Undercover (concealed), Pop-Up
Activation Automatic (thermally activated bulb)
Nozzle ID A
Operating Pressure 100 bar
K-factor 1.68
Activation Temperature 57 C
Orientation Pendent
Material CuZn36Pb2As (brass) coated with NiSn
Pipe Connection 10mm DIN 2353 M10S

Certification comparison

Certification Marine Sprinkler System SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57)
BV ✓ ✓
DNV ✓ ✓
LR ✓ ✓
MED ✓ — Not listed
SOLAS ✓ ✓

Other Fire Suppression Systems comparisons

Data sources

Marine Sprinkler System
Data from minimax.com ·
View original
SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57)
Data from components.semcomaritime.com ·
View original