Marine Deluge System vs SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems
The Minimax Marine Deluge System and Danfoss Semco SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00) are both fire suppression systems products certified to DNV and LR.
Marine Deluge System
SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
Specification comparison
| Specification | Marine Deluge System | SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00) |
|---|---|---|
| Agent Type | Water spray / drencher | |
| System Type | Deluge (open nozzle, total area coverage) | |
| Coverage Area | Car decks, tank decks, cargo holds, mooring decks | |
| Activation | Automatic or manual | |
| Variants | Water spray for cargo, drencher for car decks and gas tankers | |
| Nozzle ID | BT | |
| Operating Pressure | 60 bar | |
| K-factor | 1.258 | |
| Max Ceiling Height | 1.5 m | |
| Nozzle Spacing | 2.7 x 3.0 m | |
| Max Distance to Bulkhead | Half spacing | |
| Orientation | Pendent | |
| Material | Nozzle head: CuZn36Pb2As (brass) NiSn coated; Top: AISI 316L | |
| Pipe Connection | 12mm DIN 2353 M12L | |
| Part Number | 8068629 |
Certification comparison
| Certification | Marine Deluge System | SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00) |
|---|---|---|
| BV | ✓ | — Not listed |
| DNV | ✓ | ✓ |
| LR | ✓ | ✓ |
| MED | ✓ | — Not listed |
| SOLAS | ✓ | ✓ |
Other Fire Suppression Systems comparisons
Data sources
SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
Data from components.semcomaritime.com ·
View original