HI-FOG Sprinkler Pump Unit (SPU) vs SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Marioff HI-FOG Sprinkler Pump Unit (SPU) and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding are both fire suppression systems products certified to DNV and LR. Key difference: Operating Pressure — HI-FOG Sprinkler Pump Unit (SPU) is 80 - 140 bar vs SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding at 100 bar.

HI-FOG Sprinkler Pump Unit (SPU)
SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding

Specification comparison

Specification HI-FOG Sprinkler Pump Unit (SPU) SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding
Operating Pressure 80 - 140 bar 100 bar
Water Inlet Pressure 2 - 6 bar
Pump Modules Up to 8 modules (7+1 redundant)
Pressure Control Software control with frequency converter
Coverage Area Up to 3,284 m3
Material Stainless steel high-pressure components AISI 316 stainless steel piping
Agent Type High-pressure water mist (pure fresh water)
Nozzle Type Open deluge nozzle
Droplet Size 10 - 50 micron
System Configuration Dry pipe with manual activation (total flooding)
Activation Method Manual from valve operation panel (VOP) or bridge mimic panel
Safe for Personnel Yes (pure water, non-toxic)
Safe for Electrical Equipment Yes (IP 23 or better)

Certification comparison

Certification HI-FOG Sprinkler Pump Unit (SPU) SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding
BV — Not listed ✓
CCS — Not listed ✓
DNV ✓ ✓
LR ✓ ✓
MED — Not listed ✓
NK — Not listed ✓
SOLAS ✓ ✓
USCG — Not listed ✓

Other Fire Suppression Systems comparisons