HI-FOG Water Mist System for Naval Vessels vs SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Marioff HI-FOG Water Mist System for Naval Vessels and Danfoss Semco SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00) are both fire suppression systems products certified to DNV and LR. Key difference: Operating Pressure — HI-FOG Water Mist System for Naval Vessels is 80 - 140 bar vs SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00) at 60 bar.

HI-FOG Water Mist System for Naval Vessels
SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)

Specification comparison

Specification HI-FOG Water Mist System for Naval Vessels SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
Agent Type High-pressure water mist (pure water)
Operating Pressure 80 - 140 bar 60 bar
Coverage Area Full vessel including submarines
Material AISI 316L stainless steel tubing and fittings Nozzle head: CuZn36Pb2As (brass) NiSn coated; Top: AISI 316L
System Configuration Configurable wet pipe, pre-action, and deluge
Nozzle ID BT
K-factor 1.258
Max Ceiling Height 1.5 m
Nozzle Spacing 2.7 x 3.0 m
Max Distance to Bulkhead Half spacing
Orientation Pendent
Pipe Connection 12mm DIN 2353 M12L
Part Number 8068629

Certification comparison

Certification HI-FOG Water Mist System for Naval Vessels SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
DNV ✓ ✓
LR ✓ ✓
SOLAS ✓ ✓

Other Fire Suppression Systems comparisons

Data sources

HI-FOG Water Mist System for Naval Vessels
Data from marioff.com ·
View original
SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
Data from components.semcomaritime.com ·
View original