HI-FOG Marine Section Valves vs SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Marioff HI-FOG Marine Section Valves and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application are both fire suppression systems products certified to DNV and LR. Key difference: Operating Pressure — HI-FOG Marine Section Valves is 80 - 140 bar vs SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application at 100 bar.

HI-FOG Marine Section Valves
SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application

Specification comparison

Specification HI-FOG Marine Section Valves SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
Operating Pressure 80 - 140 bar 100 bar
Normal State Normally open, constantly monitored
Material Stainless steel AISI 316 stainless steel piping
Test Connection Built-in maintenance test port
Agent Type High-pressure water mist (pure fresh water)
Nozzle Type Open nozzle for local application
Detection Type Heat, smoke, or flame sensors (application dependent)
Activation Method Automatic via detection system; manual override available
System Configuration Dry pipe with automatic activation per section
Protected Equipment Main engines, auxiliary engines, boiler fronts, oil separators, incinerators
Safe for Electrical Equipment Yes (IP 23 or better)

Certification comparison

Certification HI-FOG Marine Section Valves SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
BV — Not listed ✓
CCS — Not listed ✓
DNV ✓ ✓
LR ✓ ✓
MED — Not listed ✓
NK — Not listed ✓
SOLAS ✓ ✓
USCG — Not listed ✓

Other Fire Suppression Systems comparisons

Data sources

HI-FOG Marine Section Valves
Data from marioff.com ·
View original
SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
Data from ttr-cms.ttrbilisim.com.tr ·
View original