HI-FOG Gas Pump Unit (GPU) vs SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57)

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Marioff HI-FOG Gas Pump Unit (GPU) and Danfoss Semco SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57) are both fire suppression systems products certified to DNV and LR. Key difference: Material — HI-FOG Gas Pump Unit (GPU) is Stainless steel high-pressure components vs SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57) at CuZn36Pb2As (brass) coated with NiSn.

HI-FOG Gas Pump Unit (GPU)
SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57)

Specification comparison

Specification HI-FOG Gas Pump Unit (GPU) SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57)
Drive Type Gas-driven mechanical piston pump
Power Source Self-contained (no external power)
Maximum Protected Height 7.5 m
Maximum Protected Volume 1500 m3
Water Source External system, tank, or cylinders
Material Stainless steel high-pressure components CuZn36Pb2As (brass) coated with NiSn
Nozzle ID A
Operating Pressure 100 bar
K-factor 1.68
Activation Temperature 57 C
Orientation Pendent
Pipe Connection 10mm DIN 2353 M10S

Certification comparison

Certification HI-FOG Gas Pump Unit (GPU) SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57)
BV — Not listed ✓
DNV ✓ ✓
LR ✓ ✓
SOLAS ✓ ✓

Other Fire Suppression Systems comparisons

Data sources

HI-FOG Gas Pump Unit (GPU)
Data from marioff.com ·
View original
SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57)
Data from components.semcomaritime.com ·
View original