HI-FOG Water Mist System for Ferries vs SEM-SAFE High-Pressure Water Mist System for Accommodation

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Marioff HI-FOG Water Mist System for Ferries and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Accommodation are both fire suppression systems products certified to DNV and LR. Key difference: Agent Type — HI-FOG Water Mist System for Ferries is High-pressure water mist (pure water) vs SEM-SAFE High-Pressure Water Mist System for Accommodation at High-pressure water mist (pure fresh water).

HI-FOG Water Mist System for Ferries
SEM-SAFE High-Pressure Water Mist System for Accommodation

Specification comparison

Specification HI-FOG Water Mist System for Ferries SEM-SAFE High-Pressure Water Mist System for Accommodation
Agent Type High-pressure water mist (pure water) High-pressure water mist (pure fresh water)
Operating Pressure 80 - 140 bar 100 bar
Coverage Area Vehicle decks, machinery, accommodation, galleys, technical spaces
Material AISI 316L stainless steel tubing and fittings AISI 316 stainless steel piping
System Configuration Wet pipe and deluge (Ro-Ro decks) Wet pipe with pressurized standby
Standby Pressure 10 - 15 bar
Nozzle Type Closed with glass bulb (automatic activation)
Activation Temperature 57 C
Droplet Size 10 - 50 micron
Nozzle Spacing Up to 5.5 m
Max Ceiling Height 2.5 m
Emergency Backup Minimum 1 minute capacity at max required flow

Certification comparison

Certification HI-FOG Water Mist System for Ferries SEM-SAFE High-Pressure Water Mist System for Accommodation
BV — Not listed ✓
CCS — Not listed ✓
DNV ✓ ✓
LR ✓ ✓
MED — Not listed ✓
NK — Not listed ✓
SOLAS ✓ ✓
USCG — Not listed ✓

Other Fire Suppression Systems comparisons

Data sources

HI-FOG Water Mist System for Ferries
Data from marioff.com ·
View original
SEM-SAFE High-Pressure Water Mist System for Accommodation
Data from ·