HI-FOG Water Mist System for Cargo Ships vs SEM-SAFE Accommodation Nozzle Type F (HNMP-4-10-2.04-57)

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Marioff HI-FOG Water Mist System for Cargo Ships and Danfoss Semco SEM-SAFE Accommodation Nozzle Type F (HNMP-4-10-2.04-57) are both fire suppression systems products certified to DNV and LR. Key difference: Operating Pressure — HI-FOG Water Mist System for Cargo Ships is 80 - 140 bar vs SEM-SAFE Accommodation Nozzle Type F (HNMP-4-10-2.04-57) at 100 bar.

HI-FOG Water Mist System for Cargo Ships
SEM-SAFE Accommodation Nozzle Type F (HNMP-4-10-2.04-57)

Specification comparison

Specification HI-FOG Water Mist System for Cargo Ships SEM-SAFE Accommodation Nozzle Type F (HNMP-4-10-2.04-57)
Agent Type High-pressure water mist (pure water)
Operating Pressure 80 - 140 bar 100 bar
Coverage Area Machinery rooms, accommodation, technical spaces
Material AISI 316L stainless steel tubing and fittings CuZn36Pb2As (brass) coated with NiSn
Nozzle ID F (3-02-48-4-22-57)
K-factor 2.04
Max Ceiling Height 2.5 m
Nozzle Spacing 2.5 m
Activation Temperature 57 C
Orientation Pendent
Max Distance to Bulkhead 1.25 m
Pipe Connection 10mm DIN 2353 M10S
Part Number 8068633

Certification comparison

Certification HI-FOG Water Mist System for Cargo Ships SEM-SAFE Accommodation Nozzle Type F (HNMP-4-10-2.04-57)
BV — Not listed ✓
DNV ✓ ✓
LR ✓ ✓
SOLAS ✓ ✓

Other Fire Suppression Systems comparisons

Data sources

HI-FOG Water Mist System for Cargo Ships
Data from marioff.com ·
View original
SEM-SAFE Accommodation Nozzle Type F (HNMP-4-10-2.04-57)
Data from components.semcomaritime.com ·
View original