Marine WHDR Wet Chemical Galley System vs SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Kidde-Fenwal Marine WHDR Wet Chemical Galley System and Danfoss Semco SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00) are both fire suppression systems products certified to DNV.

Marine WHDR Wet Chemical Galley System
SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)

Specification comparison

Specification Marine WHDR Wet Chemical Galley System SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
Agent Type Wet chemical (non-toxic)
Actuation Automatic or manual
Control System XV Control System
Max Containers 20
Temperature Range -18 to +49 C
Recharge On-board recharge capable
Nozzle ID BT
Operating Pressure 60 bar
K-factor 1.258
Max Ceiling Height 1.5 m
Nozzle Spacing 2.7 x 3.0 m
Max Distance to Bulkhead Half spacing
Orientation Pendent
Material Nozzle head: CuZn36Pb2As (brass) NiSn coated; Top: AISI 316L
Pipe Connection 12mm DIN 2353 M12L
Part Number 8068629

Certification comparison

Certification Marine WHDR Wet Chemical Galley System SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
DNV ✓ ✓
LR — Not listed ✓
SOLAS — Not listed ✓

Other Fire Suppression Systems comparisons

Data sources

Marine WHDR Wet Chemical Galley System
Data from kidde-fenwal.com ·
View original
SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
Data from components.semcomaritime.com ·
View original