Marine High Pressure CO2 Fire Suppression System vs SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems
The Kidde-Fenwal Marine High Pressure CO2 Fire Suppression System and Danfoss Semco SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00) are both fire suppression systems products certified to DNV and LR.
Marine High Pressure CO2 Fire Suppression System
SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
Specification comparison
| Specification | Marine High Pressure CO2 Fire Suppression System | SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00) |
|---|---|---|
| Agent Type | Carbon dioxide (CO2) | |
| Cylinder Capacities | 25, 35, 50, 75, 100 lb | |
| Application Types | Total flooding, local application, hand-hose line | |
| Discharge Time | <60 seconds | |
| Actuation | Solenoid or manual actuator | |
| Agent Properties | Colorless, odorless, electrically non-conductive | |
| Nozzle ID | BT | |
| Operating Pressure | 60 bar | |
| K-factor | 1.258 | |
| Max Ceiling Height | 1.5 m | |
| Nozzle Spacing | 2.7 x 3.0 m | |
| Max Distance to Bulkhead | Half spacing | |
| Orientation | Pendent | |
| Material | Nozzle head: CuZn36Pb2As (brass) NiSn coated; Top: AISI 316L | |
| Pipe Connection | 12mm DIN 2353 M12L | |
| Part Number | 8068629 |
Certification comparison
| Certification | Marine High Pressure CO2 Fire Suppression System | SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00) |
|---|---|---|
| DNV | ✓ | ✓ |
| LR | ✓ | ✓ |
| SOLAS | — Not listed | ✓ |
| USCG | ✓ | — Not listed |
Other Fire Suppression Systems comparisons
Data sources
SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
Data from components.semcomaritime.com ·