Marine High Pressure CO2 Fire Suppression System vs SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57)

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Kidde-Fenwal Marine High Pressure CO2 Fire Suppression System and Danfoss Semco SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57) are both fire suppression systems products certified to DNV and LR.

Marine High Pressure CO2 Fire Suppression System
SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57)

Specification comparison

Specification Marine High Pressure CO2 Fire Suppression System SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57)
Agent Type Carbon dioxide (CO2)
Cylinder Capacities 25, 35, 50, 75, 100 lb
Application Types Total flooding, local application, hand-hose line
Discharge Time <60 seconds
Actuation Solenoid or manual actuator
Agent Properties Colorless, odorless, electrically non-conductive
Nozzle ID A
Operating Pressure 100 bar
K-factor 1.68
Activation Temperature 57 C
Orientation Pendent
Material CuZn36Pb2As (brass) coated with NiSn
Pipe Connection 10mm DIN 2353 M10S

Certification comparison

Certification Marine High Pressure CO2 Fire Suppression System SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57)
BV — Not listed ✓
DNV ✓ ✓
LR ✓ ✓
SOLAS — Not listed ✓
USCG ✓ — Not listed

Other Fire Suppression Systems comparisons

Data sources

Marine High Pressure CO2 Fire Suppression System
Data from kidde-fenwal.com ·
View original
SEM-SAFE Accommodation Nozzle Type A (HNMP-5-10-1.68-57)
Data from components.semcomaritime.com ·
View original