Low Pressure CO2 Fire Suppression System vs SEM-SAFE High-Pressure Water Mist System for Accommodation

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The The Hiller Companies Low Pressure CO2 Fire Suppression System and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Accommodation are both fire suppression systems products certified to SOLAS and USCG. Key difference: Agent Type — Low Pressure CO2 Fire Suppression System is Carbon Dioxide (CO2) vs SEM-SAFE High-Pressure Water Mist System for Accommodation at High-pressure water mist (pure fresh water).

Low Pressure CO2 Fire Suppression System
SEM-SAFE High-Pressure Water Mist System for Accommodation

Specification comparison

Specification Low Pressure CO2 Fire Suppression System SEM-SAFE High-Pressure Water Mist System for Accommodation
Agent Type Carbon Dioxide (CO2) High-pressure water mist (pure fresh water)
Storage Type Refrigerated low-pressure tank
Storage Temperature 0 F
Agent Capacity Several tons per tank
Fire Classes Class A, B, and C
Electrical Conductivity Non-conductive
Residue Zero residue
Operating Pressure 100 bar
Standby Pressure 10 - 15 bar
Nozzle Type Closed with glass bulb (automatic activation)
Activation Temperature 57 C
Droplet Size 10 - 50 micron
Material AISI 316 stainless steel piping
Nozzle Spacing Up to 5.5 m
Max Ceiling Height 2.5 m
System Configuration Wet pipe with pressurized standby
Emergency Backup Minimum 1 minute capacity at max required flow

Certification comparison

Certification Low Pressure CO2 Fire Suppression System SEM-SAFE High-Pressure Water Mist System for Accommodation
BV — Not listed ✓
CCS — Not listed ✓
DNV — Not listed ✓
LR — Not listed ✓
MED — Not listed ✓
NK — Not listed ✓
SOLAS ✓ ✓
USCG ✓ ✓

Other Fire Suppression Systems comparisons

Data sources

Low Pressure CO2 Fire Suppression System
Data from hillerfire.com ·
View original
SEM-SAFE High-Pressure Water Mist System for Accommodation
Data from ·