High Pressure CO2 Fire Suppression System vs SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The The Hiller Companies High Pressure CO2 Fire Suppression System and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application are both fire suppression systems products certified to SOLAS and USCG. Key difference: Agent Type — High Pressure CO2 Fire Suppression System is Carbon Dioxide (CO2) vs SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application at High-pressure water mist (pure fresh water).

High Pressure CO2 Fire Suppression System
SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application

Specification comparison

Specification High Pressure CO2 Fire Suppression System SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
Agent Type Carbon Dioxide (CO2) High-pressure water mist (pure fresh water)
Fire Classes Class A, B, and C
Application Method Total flood and local application
Storage Type High pressure cylinders
Electrical Conductivity Non-conductive
Residue Zero residue
Operating Pressure 100 bar
Nozzle Type Open nozzle for local application
Detection Type Heat, smoke, or flame sensors (application dependent)
Activation Method Automatic via detection system; manual override available
Material AISI 316 stainless steel piping
System Configuration Dry pipe with automatic activation per section
Protected Equipment Main engines, auxiliary engines, boiler fronts, oil separators, incinerators
Safe for Electrical Equipment Yes (IP 23 or better)

Certification comparison

Certification High Pressure CO2 Fire Suppression System SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
BV — Not listed ✓
CCS — Not listed ✓
DNV — Not listed ✓
LR — Not listed ✓
MED — Not listed ✓
NK — Not listed ✓
SOLAS ✓ ✓
USCG ✓ ✓

Other Fire Suppression Systems comparisons

Data sources

High Pressure CO2 Fire Suppression System
Data from hillerfire.com ·
View original
SEM-SAFE High-Pressure Water Mist System for Engine Room Local Application
Data from ttr-cms.ttrbilisim.com.tr ·
View original