Galley Wet Chemical Fire Suppression System vs SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The The Hiller Companies Galley Wet Chemical Fire Suppression System and Danfoss Semco SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00) are both fire suppression systems products certified to SOLAS.

Galley Wet Chemical Fire Suppression System
SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)

Specification comparison

Specification Galley Wet Chemical Fire Suppression System SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
Agent Type Potassium carbonate (wet chemical)
Fire Classes Class K (cooking oils and fats)
Discharge Method Fine mist
Recharge On-board recharge capable
Nozzle ID BT
Operating Pressure 60 bar
K-factor 1.258
Max Ceiling Height 1.5 m
Nozzle Spacing 2.7 x 3.0 m
Max Distance to Bulkhead Half spacing
Orientation Pendent
Material Nozzle head: CuZn36Pb2As (brass) NiSn coated; Top: AISI 316L
Pipe Connection 12mm DIN 2353 M12L
Part Number 8068629

Certification comparison

Certification Galley Wet Chemical Fire Suppression System SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
DNV — Not listed ✓
LR — Not listed ✓
SOLAS ✓ ✓
USCG ✓ — Not listed

Other Fire Suppression Systems comparisons

Data sources

Galley Wet Chemical Fire Suppression System
Data from hillerfire.com ·
View original
SEM-SAFE Bilge Nozzle Type BT (HNDP-0-12-1.26-00)
Data from components.semcomaritime.com ·
View original