SEM-SAFE Cabin Sidewall Nozzle Type Z vs SEM-SAFE High-Pressure Water Mist System for Accommodation

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Danfoss Semco SEM-SAFE Cabin Sidewall Nozzle Type Z and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Accommodation are both fire suppression systems products certified to DNV and LR. Key difference: Operating Pressure — SEM-SAFE Cabin Sidewall Nozzle Type Z is 60 bar vs SEM-SAFE High-Pressure Water Mist System for Accommodation at 100 bar.

SEM-SAFE Cabin Sidewall Nozzle Type Z
SEM-SAFE High-Pressure Water Mist System for Accommodation

Specification comparison

Specification SEM-SAFE Cabin Sidewall Nozzle Type Z SEM-SAFE High-Pressure Water Mist System for Accommodation
Nozzle ID Z
Operating Pressure 60 bar 100 bar
K-factor 4.5
Max Ceiling Height 2.5 m 2.5 m
Coverage Area 4 x 6 (width x length) m
Activation Temperature 57 C 57 C
Orientation Sidewall
Nozzle Position Max 150mm below ceiling
Material Nozzle head: CuZn36Pb2As (brass) NiSn coated; Top: AISI 316L AISI 316 stainless steel piping
Pipe Connection 12mm DIN 2353 M12L
Part Number 8077172
Agent Type High-pressure water mist (pure fresh water)
Standby Pressure 10 - 15 bar
Nozzle Type Closed with glass bulb (automatic activation)
Droplet Size 10 - 50 micron
Nozzle Spacing Up to 5.5 m
System Configuration Wet pipe with pressurized standby
Emergency Backup Minimum 1 minute capacity at max required flow

Certification comparison

Certification SEM-SAFE Cabin Sidewall Nozzle Type Z SEM-SAFE High-Pressure Water Mist System for Accommodation
BV — Not listed ✓
CCS — Not listed ✓
DNV ✓ ✓
LR ✓ ✓
MED — Not listed ✓
NK — Not listed ✓
SOLAS ✓ ✓
USCG — Not listed ✓

Other Fire Suppression Systems comparisons

Data sources

SEM-SAFE Cabin Sidewall Nozzle Type Z
Data from components.semcomaritime.com ·
View original
SEM-SAFE High-Pressure Water Mist System for Accommodation
Data from ·