SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57) vs SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Danfoss Semco SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57) and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding are both fire suppression systems products certified to DNV and LR. Key difference: Operating Pressure — SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57) is 60 bar vs SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding at 100 bar.

SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57)
SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding

Specification comparison

Specification SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57) SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding
Nozzle ID AB (5-12-44-68-20-57)
Operating Pressure 60 bar 100 bar
K-factor 2.0
Flow Rate 15.5 l/min
Max Ceiling Height 2.5 m
Coverage Area 12 (centric within cabin) m2
Activation Temperature 57 C
Orientation Pendent
Material Nozzle head: CuZn36Pb2As (brass) NiSn coated; Top: AISI 316L AISI 316 stainless steel piping
Pipe Connection 12mm DIN 2353 M12L
Part Number 8074115
Agent Type High-pressure water mist (pure fresh water)
Nozzle Type Open deluge nozzle
Droplet Size 10 - 50 micron
System Configuration Dry pipe with manual activation (total flooding)
Activation Method Manual from valve operation panel (VOP) or bridge mimic panel
Safe for Personnel Yes (pure water, non-toxic)
Safe for Electrical Equipment Yes (IP 23 or better)

Certification comparison

Certification SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57) SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding
BV — Not listed ✓
CCS — Not listed ✓
DNV ✓ ✓
LR ✓ ✓
MED — Not listed ✓
NK — Not listed ✓
SOLAS ✓ ✓
USCG — Not listed ✓

Other Fire Suppression Systems comparisons

Data sources

SEM-SAFE Cabin Nozzle Type AB (HNDP-0-12-2.0-57)
Data from components.semcomaritime.com ·
View original
SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding
Data from ·