SEM-SAFE High-Pressure Water Mist System for Bilge Protection vs SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Bilge Protection and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding are both fire suppression systems products certified to DNV and LR. Key difference: Operating Pressure — SEM-SAFE High-Pressure Water Mist System for Bilge Protection is 60 bar vs SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding at 100 bar.

SEM-SAFE High-Pressure Water Mist System for Bilge Protection
SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding

Specification comparison

Specification SEM-SAFE High-Pressure Water Mist System for Bilge Protection SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding
Agent Type High-pressure water mist (pure fresh water) High-pressure water mist (pure fresh water)
Operating Pressure 60 bar 100 bar
Nozzle Type BT (dedicated bilge nozzle) Open deluge nozzle
Max Ceiling Height 1.5 m
Nozzle Spacing 2.7 x 3.0 m
K-factor 1.258
Material Nozzle head: CuZn36Pb2As (brass) NiSn coated; Top: AISI 316L AISI 316 stainless steel piping
Pipe Connection 12mm DIN 2353 M12L
Droplet Size 10 - 50 micron
System Configuration Dry pipe with manual activation (total flooding)
Activation Method Manual from valve operation panel (VOP) or bridge mimic panel
Safe for Personnel Yes (pure water, non-toxic)
Safe for Electrical Equipment Yes (IP 23 or better)

Certification comparison

Certification SEM-SAFE High-Pressure Water Mist System for Bilge Protection SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding
BV — Not listed ✓
CCS — Not listed ✓
DNV ✓ ✓
LR ✓ ✓
MED ✓ ✓
NK — Not listed ✓
SOLAS ✓ ✓
USCG — Not listed ✓

Other Fire Suppression Systems comparisons

Data sources

SEM-SAFE High-Pressure Water Mist System for Bilge Protection
Data from ·
SEM-SAFE High-Pressure Water Mist System for Engine Room Total Flooding
Data from ·