SEM-SAFE High-Pressure Water Mist System for Bilge Protection vs SEM-SAFE High-Pressure Water Mist System for Accommodation

Fire Suppression Systems comparison · 2 products · View all Fire Suppression Systems

The Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Bilge Protection and Danfoss Semco SEM-SAFE High-Pressure Water Mist System for Accommodation are both fire suppression systems products certified to DNV and LR. Key difference: Operating Pressure — SEM-SAFE High-Pressure Water Mist System for Bilge Protection is 60 bar vs SEM-SAFE High-Pressure Water Mist System for Accommodation at 100 bar.

SEM-SAFE High-Pressure Water Mist System for Bilge Protection
SEM-SAFE High-Pressure Water Mist System for Accommodation

Specification comparison

Specification SEM-SAFE High-Pressure Water Mist System for Bilge Protection SEM-SAFE High-Pressure Water Mist System for Accommodation
Agent Type High-pressure water mist (pure fresh water) High-pressure water mist (pure fresh water)
Operating Pressure 60 bar 100 bar
Nozzle Type BT (dedicated bilge nozzle) Closed with glass bulb (automatic activation)
Max Ceiling Height 1.5 m 2.5 m
Nozzle Spacing 2.7 x 3.0 m Up to 5.5 m
K-factor 1.258
Material Nozzle head: CuZn36Pb2As (brass) NiSn coated; Top: AISI 316L AISI 316 stainless steel piping
Pipe Connection 12mm DIN 2353 M12L
Standby Pressure 10 - 15 bar
Activation Temperature 57 C
Droplet Size 10 - 50 micron
System Configuration Wet pipe with pressurized standby
Emergency Backup Minimum 1 minute capacity at max required flow

Certification comparison

Certification SEM-SAFE High-Pressure Water Mist System for Bilge Protection SEM-SAFE High-Pressure Water Mist System for Accommodation
BV — Not listed ✓
CCS — Not listed ✓
DNV ✓ ✓
LR ✓ ✓
MED ✓ ✓
NK — Not listed ✓
SOLAS ✓ ✓
USCG — Not listed ✓