ZETTLER 811FEx / 601FEx-M Marine Flame Detector vs AutroSafe 4 Maritime Standard Solutions BS-420M

Fire Detection Systems comparison · 2 products · View all Fire Detection Systems

The Tyco Fire Protection (Johnson Controls) ZETTLER 811FEx / 601FEx-M Marine Flame Detector and Autronica Fire & Security AutroSafe 4 Maritime Standard Solutions BS-420M are both fire detection systems products certified to MED and SOLAS.

ZETTLER 811FEx / 601FEx-M Marine Flame Detector
AutroSafe 4 Maritime Standard Solutions BS-420M

Specification comparison

Specification ZETTLER 811FEx / 601FEx-M Marine Flame Detector AutroSafe 4 Maritime Standard Solutions BS-420M
Detection Type Solar blind IR
811FEx Type Addressable, intrinsically safe
601FEx-M Type Conventional, intrinsically safe
Variants Available 32
Detection Loops Per Panel 6/12
Loop Units Per Loop 127
Panels Per System 64
Temperature Range -25 to +70 C
Protection Class IP32

Certification comparison

Certification ZETTLER 811FEx / 601FEx-M Marine Flame Detector AutroSafe 4 Maritime Standard Solutions BS-420M
BV — Not listed ✓
DNV — Not listed ✓
LR — Not listed ✓
MED ✓ ✓
SOLAS ✓ ✓
USCG — Not listed ✓

Other Fire Detection Systems comparisons

Data sources

ZETTLER 811FEx / 601FEx-M Marine Flame Detector
Data from johnsoncontrols.com ·
View original
AutroSafe 4 Maritime Standard Solutions BS-420M
Data from product.autronicafire.com ·
View original