Omicron OGS 3.1 Gas Sampling System (Large Scale) vs Autroprime 2 Maritime Fire Alarm Control Panel BS-200M
Fire Detection Systems comparison · 2 products · View all Fire Detection Systems
The Autronica Fire & Security Omicron OGS 3.1 Gas Sampling System (Large Scale) and Autronica Fire & Security Autroprime 2 Maritime Fire Alarm Control Panel BS-200M are both fire detection systems products certified to BV and DNV.
Omicron OGS 3.1 Gas Sampling System (Large Scale)
Autroprime 2 Maritime Fire Alarm Control Panel BS-200M
Specification comparison
| Specification | Omicron OGS 3.1 Gas Sampling System (Large Scale) | Autroprime 2 Maritime Fire Alarm Control Panel BS-200M |
|---|---|---|
| Detection Type | Infrared hydrocarbon via centralised sampling | |
| System Type | Centralised monitoring cabinet with multiple detector cabinets | |
| Sampling Method | Dual vacuum pumps, automatic sequential purging | |
| Panels Per System | 8 | |
| Detection Loops Per Panel | 4 | |
| Addresses Per Loop | 127 | |
| Alarm Units Per Loop | 40 | |
| Loop Units Per Panel | 508 | |
| Communication Ports | 1x serial, 1x USB, 1x Ethernet RJ45 |
Certification comparison
| Certification | Omicron OGS 3.1 Gas Sampling System (Large Scale) | Autroprime 2 Maritime Fire Alarm Control Panel BS-200M |
|---|---|---|
| BV | ✓ | ✓ |
| DNV | ✓ | ✓ |
| LR | ✓ | ✓ |
| MED | ✓ | ✓ |
| SOLAS | ✓ | ✓ |
Other Fire Detection Systems comparisons
Data sources
Omicron OGS 3.1 Gas Sampling System (Large Scale)
Data from product.autronicafire.com ·
View original
Autroprime 2 Maritime Fire Alarm Control Panel BS-200M
Data from product.autronicafire.com ·
View original