MSA M1 Marine SCBA vs Drager Saver PP15
Breathing Apparatus comparison
·
2 products
·
View all Breathing Apparatus
The MSA Safety MSA M1 Marine SCBA and Drager Saver PP15 are both breathing apparatus products certified to MED and SOLAS. Key difference: Weight — MSA M1 Marine SCBA is <4 kg vs Drager Saver PP15 at 6.18 kg.
Specification comparison
Specification
MSA M1 Marine SCBA
Drager Saver PP15
Weight
<4 kg
6.18 kg
Demand Valve
M1 LGDV, AS type, Push-to-connect
Gauge
Classic mechanical gauge (JG)
Pneumatics
ClassicLine (C1)
Backplate
Fixed height (BNA)
Cylinder Band
Single, plastic buckle (SP)
Harness
Basic, plastic buckle (BP)
Temperature Range
-40 to +60 C
-15 - +60 C
Compatible Cylinders
4.7L to 9.0L, 200/300 bar
Compatible Mask
G1 Full Facemask (10202909)
Escape Time
15 min
Dimensions
490 x 160 x 250 mm
Cylinder Free Capacity
600 l
Cylinder Water Capacity
3 l
Maximum Working Pressure
200 bar
Medium Pressure
6 - 9 bar
Airflow to Hood
500 l/min
Certification comparison
Certification
MSA M1 Marine SCBA
Drager Saver PP15
LR
— Not listed
✓
MED
✓
✓
SOLAS
✓
✓
Other Breathing Apparatus comparisons
The equipment specifications, certification references, and compliance data presented on SOLASindex have been compiled from publicly available manufacturer websites and documentation. This information is provided for reference purposes only.
SOLASindex does not certify, endorse, or recommend any product or manufacturer. We are an information platform, not a certification body, marketplace, or regulatory authority.
This information is not a substitute for:
Official product documentation from the manufacturer
Current certification records from classification societies or the EMSA MED Portal
Regulatory compliance verification with your flag state authority
Professional procurement or maritime safety advice
Equipment certifications may expire, be modified, suspended, or withdrawn at any time. Specifications may change between production runs. Always verify current certification status, specifications, and SOLAS compliance directly with the manufacturer and your classification society before making procurement decisions.
Data accuracy: While we strive to present accurate and current information, we do not warrant or guarantee the completeness, accuracy, or currency of any data displayed. Information reflects what was publicly available at the time of extraction.
Manufacturers: If any data about your products is inaccurate, claim your listing to correct it directly, or contact us at corrections@networklayer.ai . We will address reported inaccuracies within 5 business days.