Emergency Evacuation Breathing Device ESCAPE-15 (EEBD) vs Drager Saver CF15
Breathing Apparatus comparison
·
2 products
·
View all Breathing Apparatus
The LALIZAS Emergency Evacuation Breathing Device ESCAPE-15 (EEBD) and Drager Saver CF15 are both breathing apparatus products certified to MED and SOLAS. Key difference: Temperature Range — Emergency Evacuation Breathing Device ESCAPE-15 (EEBD) is -10 - +65 C vs Drager Saver CF15 at -15 - +60 C.
Emergency Evacuation Breathing Device ESCAPE-15 (EEBD)
Specification comparison
Specification
Emergency Evacuation Breathing Device ESCAPE-15 (EEBD)
Drager Saver CF15
Service Life
15 minutes
Temperature Range
-10 - +65 C
-15 - +60 C
Color
Silver (heat reflective)
Service Life
15 minutes
Part Number
70321
Escape Time
15 min
Dimensions
510 x 260 x 190 mm
Weight
6.9 kg
Cylinder
3 L, 200 bar, steel
Airflow to Hood
35 - 37 l/min
Material
Flame retardant, washable, natural rubber neck seal
Certification comparison
Certification
Emergency Evacuation Breathing Device ESCAPE-15 (EEBD)
Drager Saver CF15
LR
— Not listed
✓
MED
✓
✓
SOLAS
✓
✓
Other Breathing Apparatus comparisons
Data sources
Emergency Evacuation Breathing Device ESCAPE-15 (EEBD)
Data from lalizas.com ·
View original
The equipment specifications, certification references, and compliance data presented on SOLASindex have been compiled from publicly available manufacturer websites and documentation. This information is provided for reference purposes only.
SOLASindex does not certify, endorse, or recommend any product or manufacturer. We are an information platform, not a certification body, marketplace, or regulatory authority.
This information is not a substitute for:
Official product documentation from the manufacturer
Current certification records from classification societies or the EMSA MED Portal
Regulatory compliance verification with your flag state authority
Professional procurement or maritime safety advice
Equipment certifications may expire, be modified, suspended, or withdrawn at any time. Specifications may change between production runs. Always verify current certification status, specifications, and SOLAS compliance directly with the manufacturer and your classification society before making procurement decisions.
Data accuracy: While we strive to present accurate and current information, we do not warrant or guarantee the completeness, accuracy, or currency of any data displayed. Information reflects what was publicly available at the time of extraction.
Manufacturers: If any data about your products is inaccurate, claim your listing to correct it directly, or contact us at corrections@networklayer.ai . We will address reported inaccuracies within 5 business days.